Pedro Nuno Basso Neves
AuthID: R-000-F29
11
TÃTULO: Experimental Measurement of the Ne and Ne+ and Ne-2(+) Mobilities in Ne and the Reaction Rate Coefficient for Ne++2Ne -> Ne-2(+) + Ne Full Text
AUTORES: Neves, PNB; Garcia, ANC; Trindade, AMF; Barata, JAS ; Tavora, LMN; Conde, CAN ;
PUBLICAÇÃO: 2011, FONTE: IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOLUME: 58, NÚMERO: 4
AUTORES: Neves, PNB; Garcia, ANC; Trindade, AMF; Barata, JAS ; Tavora, LMN; Conde, CAN ;
PUBLICAÇÃO: 2011, FONTE: IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOLUME: 58, NÚMERO: 4
INDEXADO EM:
Scopus
WOS


12
TÃTULO: Drift field limitations to the energy resolution in Time Projection Chambers for Xe-136 neutrino-less double beta decay search Full Text
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2011, FONTE: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, VOLUME: 641, NÚMERO: 1
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2011, FONTE: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, VOLUME: 641, NÚMERO: 1
13
TÃTULO: Experimental Measurement of H-3(+)/H-5(+) and D-3(+)/D-5(+) mobilities in their parent gases
AUTORES: Neves, PNB; Escada, J; Borges, FIGM; Tavora, LMN; Conde, CAN;
PUBLICAÇÃO: 2011, FONTE: IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors in 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC)
AUTORES: Neves, PNB; Escada, J; Borges, FIGM; Tavora, LMN; Conde, CAN;
PUBLICAÇÃO: 2011, FONTE: IEEE Nuclear Science Symposium/Medical Imaging Conference (NSS/MIC)/18th International Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors in 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC)
INDEXADO EM:
WOS

14
TÃTULO: Experimental Measurement of the <formula formulatype="inline"> <tex Notation="TeX">${\hbox{Ne}}^{+}$</tex></formula> and <formula formulatype="inline"> <tex Notation="TeX">${\hbox{Ne}}_{2}^{+}$</tex></formula> Mobilities in Ne and the Reaction Rate Coefficient for <formula formulatype="inline"><tex Notation="TeX">${\hbox{Ne}}^{+} + 2{\hbox{Ne}} \ura{} {\hbox{Ne}}_{2}^{+} +{\hbox{Ne}}$</tex></formula> Full Text
AUTORES: Neves, PNB; Garcia, ANC; Trindade, AMF; Barata, JAS; Tavora, LMN; Conde, CAN;
PUBLICAÇÃO: 2011, FONTE: IEEE Trans. Nucl. Sci. - IEEE Transactions on Nuclear Science, VOLUME: 58, NÚMERO: 4
AUTORES: Neves, PNB; Garcia, ANC; Trindade, AMF; Barata, JAS; Tavora, LMN; Conde, CAN;
PUBLICAÇÃO: 2011, FONTE: IEEE Trans. Nucl. Sci. - IEEE Transactions on Nuclear Science, VOLUME: 58, NÚMERO: 4
15
TÃTULO: The X++2X -> X-2(+) + X reaction rate constant for Ar, Kr and Xe, at 300 K Full Text
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2010, FONTE: 11th International Symposium on Radiation Physics in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, VOLUME: 619, NÚMERO: 1-3
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2010, FONTE: 11th International Symposium on Radiation Physics in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, VOLUME: 619, NÚMERO: 1-3
16
TÃTULO: Photopeak shift effects due to the drift electric field in high pressure xenon detectors
AUTORES: Neves, PNB; Barata, JAS ; Tavora, LMN; Dias, THVT ; Borges, FIGM ; Conde, CAN ;
PUBLICAÇÃO: 2010, FONTE: IEEE Nuclear Science Symposium (NSS)/Medical Imaging Conference (MIC)/17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors in 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC)
AUTORES: Neves, PNB; Barata, JAS ; Tavora, LMN; Dias, THVT ; Borges, FIGM ; Conde, CAN ;
PUBLICAÇÃO: 2010, FONTE: IEEE Nuclear Science Symposium (NSS)/Medical Imaging Conference (MIC)/17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors in 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC)
17
TÃTULO: Experimental measurement of the mobilities of atomic, Ne+, and dimer, Ne-2(+), ions in Ne
AUTORES: Garcia, ANC; Trindade, AMF; Oliveira, TDP; Neves, PNB; Barata, JAS ; Tavora, LMN; Dias, THVT ; Borges, FIGM ; Conde, CAN ;
PUBLICAÇÃO: 2010, FONTE: IEEE Nuclear Science Symposium (NSS)/Medical Imaging Conference (MIC)/17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors in 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC)
AUTORES: Garcia, ANC; Trindade, AMF; Oliveira, TDP; Neves, PNB; Barata, JAS ; Tavora, LMN; Dias, THVT ; Borges, FIGM ; Conde, CAN ;
PUBLICAÇÃO: 2010, FONTE: IEEE Nuclear Science Symposium (NSS)/Medical Imaging Conference (MIC)/17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors in 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC)
INDEXADO EM:
Scopus
WOS


18
TÃTULO: Measuring the mobilities of the ions formed in P-10 mixtures
AUTORES: Neves, PNB; Trindade, AMF; Barata, JAS ; Tavora, LMN; Conde, CAN ;
PUBLICAÇÃO: 2009, FONTE: IEEE Nuclear Science Symposium Conference 2009 in 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5
AUTORES: Neves, PNB; Trindade, AMF; Barata, JAS ; Tavora, LMN; Conde, CAN ;
PUBLICAÇÃO: 2009, FONTE: IEEE Nuclear Science Symposium Conference 2009 in 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5
19
TÃTULO: A new experimental technique for positive ion drift velocity measurements in noble gases: Results for xenon ions in xenon Full Text
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2007, FONTE: 10th International Symposium on Radiation Physics in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, VOLUME: 580, NÚMERO: 1
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2007, FONTE: 10th International Symposium on Radiation Physics in NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, VOLUME: 580, NÚMERO: 1
20
TÃTULO: Experimental measurement of the mobilities of argon ions in gaseous argon
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2007, FONTE: 2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD in IEEE Nuclear Science Symposium Conference Record, VOLUME: 2
AUTORES: Neves, PNB; Conde, CAN ; Tavora, LMN;
PUBLICAÇÃO: 2007, FONTE: 2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD in IEEE Nuclear Science Symposium Conference Record, VOLUME: 2
INDEXADO EM:
Scopus
CrossRef

